lunes, 28 de febrero de 2011

Service Provided to M/T SICHEM ONOMICHI 2011







Auxiliary Boiler Valves Overhaul.-
M/T SICHEM ONOMICHI
Description
Auxiliary Boiler Valves Overhaul: The following valves were Dismounted and Dismantled for overhaul, cleaned, lapped, gasket and gland packing changed, refitted back to boiler and pressure tested.
Main Steam stop valve: 10K-150 straight globe valve.
Circulating water pump 's inlet valve: 10K-65 straight globe valve
Circulating water pump 's outlet valve: 10K-65 straight globe valve.
Feed water Inlet valve: 10K-50 Straight globe valve
Bottom blow down valve: 16K-40 Straight globe valve
Overhauled of Main Steam Stop Valves: Deck main steam line valve (In HPPE) was Dismounted and Dismantled for overhaul, cleaned, lapped, gasket and gland packing changed, refitted back to boiler and pressure test. Spec. size-10K-150A Straight globe.

No hay comentarios:

Publicar un comentario